Basic measuring range of thermal air mass flow meters
Choose a flowmeter and understanding the measurement range of the flowmeter can help us make a better choice.
View MoreWith the increasing air pollution problem, air quality monitoring has become an increasingly important topic.
With the increasing air pollution problem, air quality monitoring has become an increasingly important topic. In air quality monitoring, an air mass flow meter is a very critical piece of equipment that can be used to measure the air flow rate at an air quality monitoring station to ensure the accuracy of the monitoring data. Therefore, both quality and reliability are factors to be considered when selecting and maintaining air mass flow meters.
Selection
When selecting an air mass flow meter, the following aspects need to be considered:
1.1 Measuring range
Different air mass flow meters have different measuring ranges. When selecting a model, you need to choose the appropriate measuring range according to the needs of the monitoring site.
1.2 Measurement accuracy
Measurement accuracy is one of the important indexes of air mass flow meters, which affects the accuracy of monitoring data. When selecting the type, it is necessary to choose the air mass flow meter with higher accuracy.
1.3 Environmental requirements
The environmental requirements of air mass flow meter include temperature, humidity, air pressure and so on. When selecting, it is necessary to choose the suitable air mass flow meter according to the actual situation of the monitoring station.
1.4 Maintenance requirements
Maintenance requirements of air mass flow meter include cleaning, calibration, etc. When selecting the model, it is necessary to choose a suitable air mass flow meter that is easy to use. When selecting the type, it is necessary to choose the air mass flow meter that is easy to maintain.
Maintenance Tips
Air mass flow meters require regular maintenance during use, the following are some common maintenance techniques:
2.1 Cleaning
Air mass flow meters need to be cleaned regularly to ensure measurement accuracy. When cleaning, care needs to be taken not to use hard objects such as a scale, so as not to scratch the surface of the sensor. It is best to use special cleaners and cotton swabs when cleaning.
2.2 Calibration
The air mass flow meter needs to be calibrated periodically to ensure the measurement accuracy. When calibrating, you need to pay attention to the use of correct calibration equipment and methods, and carry out measurement verification after calibration.
2.3 Replacement of Components
The components of the air mass flow meter will wear out with the increase of use time and need to be replaced periodically to ensure the reliability of the equipment. When replacing parts, it is necessary to pay attention to the use of original spare parts and replace them according to the requirements of the manual.
Summarize
In air quality monitoring, air quality flow meter is an important equipment, selection and maintenance are critical. Selection needs to consider the measurement range, measurement accuracy, environmental requirements and maintenance requirements and other factors to ensure that the selected equipment can meet the actual needs. Maintenance requires attention to cleaning, calibration and replacement of parts to ensure the stability and reliability of the equipment.
The magnetic inductive flowmeter industry, these are successful cases with comparable and reference value.
Choose a flowmeter and understanding the measurement range of the flowmeter can help us make a better choice.
View MoreThe orifice plate flowmeter flare should be installed facing upstream to minimize resistance and measurement errors and to reduce vortex disturbances.
View MoreThe integrated balanced flow meter consists of a primary occlusion (sensing) element, a differential pressure transmitter and a three-valve group.
View MoreHangzhou Economic Development Area,Hangzhou 310018,China