How do you calculate how many tons of steam vortex flowmeter?
The measurement of steam vortex flowmeter includes three important parameters: pressure, temperature and frequency.
View MoreThermal resistor is transmitted to the central control and displays inconsistently.
Thermal resistor is a commonly used sensor in temperature measurement. It converts changes in temperature into changes in resistance. The inconsistency in the display of the thermal resistor transmitted to the central control may be caused by a variety of reasons. The specific reasons need to be found out through system troubleshooting and testing.
Main reasons
The main reasons for the inconsistency in the thermal resistor transmission to the central control display are as follows:
1. Thermal resistor itself is faulty
The fault of the thermal resistor itself is one of the main reasons for inconsistent display. After the thermal resistor is used for a long time, problems such as aging, damage or drift may occur, causing its resistance value to change, thus affecting the measurement accuracy.
2. Line connection problems
Insufficient line connection or poor contact will also cause the thermal resistance to be transmitted to the central control display inconsistently. Loose or damaged connecting wires or oxidation at the joints will affect signal transmission and lead to abnormal measurement data.
3. Instrument failure
Failure of the central control instrument will also cause inconsistent thermal resistance display. Damage to the internal components of the instrument, program errors or abnormalities in the display module will affect the processing and display of the thermal resistance signal.
4. Electromagnetic interference
Electromagnetic interference will affect the transmission of thermal resistance signals and the normal operation of central control instruments. Interference generated by strong electromagnetic fields or other electronic equipment may cause abnormal readings of the thermal resistor.
Troubleshooting method
To eliminate the problem of inconsistent display of the thermal resistor transmitted to the central control, you can proceed through the following steps:
1. Check the thermal resistor
Use a multimeter to measure the resistance value of the thermal resistor and check whether it is within the normal range. If the resistance value is abnormal or changes significantly, the thermal resistor needs to be replaced.
2. Check the circuit connection
Check whether the circuit connection between the thermal resistor and the central control instrument is firm and reliable, and whether there is any looseness, damage or poor contact. If necessary, the wiring can be reconnected or replaced.
3. Test the instrument
Use an oscilloscope or other instrument to test the processing process of the thermal resistance signal by the central control instrument. Check whether the instrument receives and processes signals normally and whether there is any abnormal output.
4. Eliminate electromagnetic interference
Check whether there are strong electromagnetic field sources near the thermal resistor and lines, and take appropriate shielding or isolation measures to avoid electromagnetic interference affecting signal transmission.
Notes
When troubleshooting the problem of inconsistent display between the thermal resistor and the central control, you need to pay attention to the following points:
1. Ensure that the thermal resistor and circuit Make connections correctly and use appropriate instruments and tools for testing.
2. During the troubleshooting process, avoid damage to the equipment or risk of electric shock.
3. If the problem cannot be solved by self-examination, please contact personnel for maintenance in time.
Conclusion
Thermal resistance is transmitted toInconsistent display on the center console is a common problem and can be caused by a variety of factors. Through system troubleshooting and testing, specific causes can be found and corresponding solutions can be taken. Only by ensuring the normal operation of the thermal resistor and central control instrument can the accuracy and reliability of the temperature data be ensured.
The magnetic inductive flowmeter industry, these are successful cases with comparable and reference value.
The measurement of steam vortex flowmeter includes three important parameters: pressure, temperature and frequency.
View MoreThe high-temperature vortex flowmeter is an instrument specially used to measure the flow of high-temperature media.