Magnetic Flip-Flop Level Gauge to measure liquefied gas application

Time: 2025-01-08
Equipment Configuration:Magnetic Flip-Flop Level Gauge

Magnetic flap level meter can be used to measure the liquid level of liquefied gas.

Project Overview

Application of magnetic flap level meter in liquefied gas measurement:

Magnetic flap level meter can be used to measure the liquid level of liquefied gas. The material is made of materials that are resistant to cavitation of liquefied gas. We won’t go into the principle here. You can understand it by directly looking at the basic magnetic flap level meter.

Here is a user case to analyze the application of liquefied gas magnetic flap level meter in liquefied gas measurement.

User asked: Recently, the liquid level of the magnetic flap liquid level meter used in our factory to measure C4 liquefied gas has always been high and low at noon in the past two days. After turning it off and turning it on, The float is also fine, and the gas and liquid phase valves are also fine and flowing smoothly. What is the reason?

Answer: There are generally two reasons for this phenomenon:

1. The liquid vaporizes, and the liquid vaporizes to produce The so-called gas blockage phenomenon is that a liquid with a low boiling point vaporizes at a certain point or section in the pipeline due to the increase in external local temperature. The vaporized gas is not removed immediately due to other reasons and stays here to occupy a considerable space. And block the flow of liquid, forming air blockage of liquid.

2. It may be that the float is stuck, the thickness of the steel pipe selected was too small, or there may be large foreign objects inside that sometimes get stuck on the float, causing a false liquid level.

The third phenomenon will basically not occur, and the magnetism of the float will be significantly weakened.

For liquefied gas measurement, the most likely cause of this phenomenon is vaporization. In this case, if you purchased our magnetic flap level meter at that time, it should be It is customized according to the specific actual parameters on site, and gasification is fully considered when customizing the float density.