Magnetic float level gauge working principle and technical parameters

Time: 2025-01-07
Equipment Configuration:Magnetic float level gauge

Through magnetoelectric conversion, the change in liquid level is converted into a standard 4~20mA current signal or a local pointer display.

Project Overview

Principle: Through magnetoelectric conversion, the change in liquid level is converted into a standard 4~20mA current signal or a local pointer display; the output of the transmitter is divided into three forms: a local pointer display form, a local pointer display form, and a local pointer display form. Percent scale; remote transmission output mode, output standard 4~20mA current signal; local and remote transmission output mode, both local pointer and remote transmission output standard 4~20mA current signal.

The liquid level of the magnetic float ball can be independently set for the upper and lower limit alarm switches of the liquid level according to user requirements (the alarm switch is controlled by an independent switch circuit).

All measuring parts of the magnetic float level transmitter are made of stainless steel, and the internal control circuit is completely sealed. A variety of connection forms, magnetic floats and flange standards are available for users to choose from (or flange standards are based on user requirements). For measuring corrosive media, measuring components in the form of PTFE are available for users.

Power supply for the circuit part of the magnetic float level transmitter: two-wire 24VDC.

Structure and application:

The magnetic float level transmitter consists of a magnetic float, connecting parts, measuring conduit, wiring shell and output circuit.

The magnetic float level transmitter can measure ordinary liquids and flammable liquids with a medium density greater than 0.65g/cm3, and can also measure surfaces covered with thick steam, Foam or liquid mixed with gas. Widely used in shipbuilding, power generation, petroleum, chemical, food, pharmaceutical, water treatment and other industries.

Electrical parameters:

Power supply: 12 ~ 36 VDC

Output current: 4 ~ 20 mA

Maximum load resistance: Ri = (Us-12)/0.02A

Casing protection level: IP65

Lead connector: M20X1.5, PG13.5 (intrinsically safe)

1/2''-11NPT (flameproof type)

Technical parameters:

The user is responsible for strictly complying with the application and technical regulations of the instrument

Instrument

Model: UHZ

Measuring range: H≤4850mm

Insertion depth:

L≤5000mmL-H≥140mm

Accuracy level:

Measuring range: H≥1000mm

Resolution: ±6.5mm

Measuring range: 500mm≤H≤1000mm

Resolution:

±10mm

Measurement medium conditions:

Ambient temperature: -20℃ ~ 85℃

Medium Temperature: -20℃ ~ 100℃

Media density:

≥0.65g/cm3

Working pressure: ≤1.0MPa (special maximum does not exceed 2.5MPa)

Medium viscosity: ≤0.7Pas

Connection form: Flange connection:...according to DIN2501

Flange standard standard type:

DN100 PN1.0

Threaded connection form: 1 1/2'' - 11

(Threaded connection is suitable for open containers or closed containers with manholes)

Explosion-proof level: ExiaIICT6 (intrinsically safe)

ExdIICT6 (explosionproof)

Wiring housing: cast aluminum 102 (explosionproof)

PPO+FRP (intrinsically safe)

Switch 220V AC1A

220V AC0.5A