Received feedback from users regularly: The measurement data of the intelligent vortex flowmeter is obviously on the high side.
Project Overview
Received feedback from users regularly: The measurement data of the intelligent vortex flowmeter is obviously on the high side. Since the user installed it themselves, our company immediately sent after-sales technicians to the site after receiving feedback from the user.
After on-site inspection, it was found that there were no problems with the flowmeter parameter settings and wiring, but that the straight pipe section for installation was insufficient, and the distance between the vortex flowmeter and the front-end valve straight pipe section was not enough (the inconsistent outer diameter of the pipe is due to the insulation thickness inconsistent). After-sales technicians removed the vortex flowmeter for inspection and found that the upper part of the vortex generator was significantly darker than the lower part, which was caused by irregularities in the fluid in the pipe. Subsequently, the installation location was changed under the guidance of technical personnel, and the flow rate was normal.
Installation Precautions
1. The pipeline must be purged before installation to prevent damage to the instrument caused by the impact of debris.
2. Reserve enough straight pipe section for installation so that the front end of the flow meter is not too close to the valve.
3. The vortex flowmeter should be installed on a pipe without mechanical vibration as much as possible.
4. The vortex flowmeter should be installed as far away from magnetic and electrical interference as possible.
5. The inner diameter of the pipe must be the same as the inner diameter of the flow meter. If they are different, a pipe slightly larger than the diameter of the sensor should be used. Error: ≤3%.
6. Welding with a vortex flowmeter is strictly prohibited to avoid damage to the circuit board due to excessive welding current.
Schematic diagram of reserved straight pipe section
The correct installation of the intelligent vortex flowmeter directly affects its measurement accuracy, so it is recommended to contact the manufacturer's technical personnel for consultation before installation.
Qingdao Hesheng Measurement and Control, a manufacturer of intelligent vortex flow meters, has established a complete pre-sales, sales and after-sales service system. Pre-sales technicians conduct on-site inspections of users' working conditions, help users choose appropriate flow meter models, and customize flow measurement solutions; provide detailed product and service information during sales, deliver products and provide services on time with quality and quantity; and respond to user needs 24 hours a day after sales , providing on-site guidance and installation services, and regular product and system training to ensure accurate flow measurement. For questions related to flow measurement, please contact Qingdao Hesheng Measurement and Control at any time!